Skip to content
Align by NETLCO
Sign in
Training

Learn to measure a sound system

Seven lessons in the order the trade works, from the screen and the rig to correcting and checking the result. Free to read, with no account; lessons 4 to 7 use Pro's parts and say so.

Where do I start?

The seven lessons

  1. 1

    The screen

    Where everything sits

  2. 2

    The basics

    Signals, the transfer function, reference and measurement, magnitude and phase, coherence, delay, levels

  3. 3

    Check the rig

    Laptop, interface, microphone and processor connected; then, with Pro, the channel check: good data before anything

  4. 4Pro

    Measure

    The generator, the delay, the measurement

  5. 5Pro

    Read it

    The magnitude as the EQ's roadmap, phase as timing, coherence

  6. 6Pro

    Correct

    Capture, then EQ by the three rules; one seat is never flattened

  7. 7Pro

    Verify

    More positions, then listen; knowing when to stop

Lesson 1Free

The screen

Align is one screen, laid out the way a system engineer already works. Five parts hold everything, and each keeps its place.

  • The menu bar, along the top

    File to Help, with the connection on the right. Help, Keyboard shortcuts lists the keys.

  • The Data bar, on the left

    The traces first: the live measurement, frozen ones and the ones you keep. The Target at its foot. On a phone it opens from its rail, the button named Show data bar.

  • The graph, in the middle

    The screen you are on, its graph first and largest: Real-time, Impulse and SPL, then EQ, Positions and Check. Before anything is measured it draws nothing, and the line under it says how to start.

  • The Control bar, on the right

    The screens, the inputs and the measurement settings, with the generator at its foot, always open. On a phone it opens from its rail, Show control bar.

  • The command bar, along the bottom

    Plain labelled buttons for what you press most, Capture among them.

Done when: You can find the generator, your traces and Capture without searching.

Next: lesson 2, The basics
Lesson 2Free

The basics

A few ideas carry every measurement. Each is one of the words at the foot of this page, said in a sentence, with more behind it.

  • Two signals, compared

    A transfer function compares what the system is fed, the reference, with what the microphone hears, the measurement. What differs between them is the system and the room, and that difference is what Align draws.

  • In time

    The microphone hears the sound later than the reference carries it, so the delay between them is found and inserted before the two are compared.

Done when: You can say what the reference is, and why the microphone hears it late.

Next: lesson 3, Check the rig
Lesson 3Free

Check the rig

Connect the rig as drawn, then let Align see the inputs. With Pro, the channel check comes next: nothing measured is trusted until it passes.

  • What you need

    A computer with Chrome or Edge, an audio interface with at least two inputs, and a measurement microphone. Chrome and Edge let a page ask an interface for its channels; Firefox and Safari do not.

  • How it connects

    The interface plugs into the computer, and its output feeds the processor or the desk, which feeds the amplifiers and the speakers. The microphone goes into one input. The reference goes into the other: a split of what the system is fed, or a loopback cable from the interface's own output. Without a loopback, Align's own output is the reference and the delay it finds is relative.

  1. ComputerChrome or Edge, with Align open
  2. Audio interfaceTwo inputs at least
  3. Processor or deskWhat the system is fed
  4. Amplifiers and speakersThe system you measure
  • Measurement microphone, into one inputWhere the audience listens. It is the measurement.
  • The reference, into the other inputA split of what the system is fed, or a loopback cable from the interface's own output. With neither, Align's own output is the reference and the delay is relative.
The computer plays the generator through the interface into the system, and the interface brings back two things to compare: what the microphone hears and what the system was fed.
  1. Step 1

    Connect interface

    The browser asks for two discrete channels with all processing off. Align reads your interface's inputs and plays its generator through its outputs.

    Why: Nothing can be measured until the browser hands Align the inputs.

    1. In the Control bar, press Connect.
    2. Allow the browser's microphone request, and choose your interface if it asks.
    3. On a phone the Control bar is closed: open it from its rail on the right edge, the button named Show control bar.

    When it worked: The button reads Reconnect and the inputs' meters move. From 768 px wide, the menu bar says Connected.

  2. Step 2

    Pro

    Channel check

    Signal into channel 1 only. It proves the browser is not summing your inputs.

    Why: A browser can mix the two inputs into one and hand the same signal over twice. Every comparison after that would be false, so nothing measured is trusted until the check passes.

    1. Put a steady signal into input 1 only, with input 2 disconnected and silent: the generator (step 4) through a cable from an output into input 1, or a feed from the desk.
    2. Open the Check tab and press Run channel check, 5 seconds.
    3. Keep the signal running and leave the gain alone until it finishes.

    When it worked: The status reads PASS. PASS, SWAPPED means the signal arrived on input 2, and step 3 then takes input 2. FAIL, SUMMED means the browser is summing; FAIL, MONO means the device sends one channel.

  3. Step 3

    Pro

    Reference and measurement

    The reference is the electrical split of what the system is fed; the microphone is the measurement.

    Why: Align compares the two. With the inputs the wrong way round, the transfer function draws the system upside down, every rise as a dip.

    1. The reference is what the system is fed: a split of the feed, or Align's own output through the internal loop. The measurement is the microphone.
    2. After a pass, step 3 of the Guide (the Guide button at the top) sets the reference to the input the check found.
    3. A transfer function names both in its dialog.

    When it worked: The reference input carries Ref in the Control bar's inputs, or the loop's own level shows. On a phone step 3 opens the Data bar, so open the Control bar from its rail to see it.

  • Free: what the microphone hears, the RTA

    Real-time draws each input's level by frequency, a line for every frequency. Choose bars in the graph's bottom right corner, from Bars 1 oct down to Bars 1/24, and press Peak hold at its bottom left, or P, so each band keeps the highest level it has reached. The level is relative: read the shape, and one band against another.

  • Free: how loud it is, the SPL meter

    The SPL screen reads the level a person hears. With a steady signal playing, type what your reference meter reads under What your reference meter reads, dB SPL, and press Calibrate: from then on it reads dB SPL in A, C or Z weighting, Fast or Slow, with three Leq at once. With Pro, Start log keeps the moving 15 minute LAeq, the measure of the World Health Organization's safe listening limit for venues, 100 dB, for a one page report.

Done when: The inputs' meters move, the RTA draws what the microphone hears, and with Pro the channel check reads PASS.

Next: lesson 4, Measure
Lesson 4Pro

Measure

Play the system, find its delay, and let the transfer function settle: Learn's steps 4 to 6, in their own words.

  1. Step 4

    Start generator

    Pink noise, faded in, into the system under test.

    Why: The transfer function needs signal across the whole range on both inputs.

    1. At the Control bar's foot, choose Pink for measuring.
    2. Switch the generator from Off to On. It fades in and plays through the outputs.
    3. Set the level so the inputs read about -12 to -6 dBFS and never clip.

    When it worked: Both inputs' meters move and nothing clips.

  2. Step 5

    Pro

    Find delay

    Needs signal on both inputs at the moment you press it. Choose Sub or Top to time one box while the whole system plays.

    Why: The microphone hears the sound later than the reference carries it. Left out, coherence falls at the top end and the phase spins.

    1. With signal on both inputs, press Find on the transfer function's row.
    2. Then press Insert to apply what it found.

    When it worked: A delay in ms, and coherence rising at the top end.

  3. Step 6

    Pro

    Measure

    Watch the transfer function settle and the coherence rise.

    Why: A trace read before it settles shows noise, not the system.

    1. Open Real-time and the transfer function.
    2. Let the magnitude settle and the coherence rise.
    3. Trust a frequency where coherence is high.

    When it worked: Coherence near 1 where you will correct, and the trace's light green.

Done when: A delay in ms, and coherence near 1 where you will correct.

Next: lesson 5, Read it
Lesson 5Pro

Read it

Three lines on the graph answer three questions: what to correct, whether it is in time, and what to trust.

  • The magnitude is the EQ's roadmap

    Where the trace sits above the target, a cut can bring it down. Where it falls below, ask why before boosting: a rolloff or a deep null has no energy to lift, and a dip narrower than about half an octave moves when the microphone moves. That is why the three rules refuse both.

  • Phase is timing

    With the delay left out, the phase spins and coherence falls at the top end. Where two bands overlap, their phase must agree for them to add, and Auto Phase finds the delay and polarity, or an all-pass, that makes them agree.

  • Coherence says what to trust

    Read the magnitude and phase only where coherence stays near 1. Where it falls, the line there shows noise, reflections or a delay left out rather than the system. Each live trace carries a confidence light, green, amber or red, judged once a second; point at it for the reason: clipping, no signal, a delay not inserted, low-end noise such as wind, a falling high end, or noise and reflections.

  • With no interface

    File, Load the worked example opens the EQ screen on a generated trace, so its magnitude and phase can be read. It carries no coherence, so that half of this lesson needs an interface.

Done when: You can point at what to correct, say whether it is in time, and say which part to trust.

Next: lesson 6, Correct
Lesson 6Pro

Correct

Keep a measurement, then let Align fit filters toward your target under its three rules.

  1. Step 7

    Pro

    Capture trace

    Keep it; the noise stops so the room goes quiet while you name it and choose its folder.

    Why: The EQ works from a kept measurement, never from the moving live one.

    1. Press Capture on the command bar and name the trace by its position.
    2. A capture stops the noise, so switch the generator on again to measure the next position.

    When it worked: The trace appears in the Data bar.

  2. Step 8

    Pro

    Analyze and EQ

    Filters, with the regions deliberately left alone and why, fitted toward your target.

    Why: This is the correction itself, the reason for every step before it.

    1. Open EQ with the trace chosen. Align fits filters toward the target under its three rules.
    2. Correct broadly first, and measure again after each change.
    3. Never flatten one seat with many filters: the second rule exists because a narrow dip moves when the microphone moves.

    When it worked: The corrected prediction follows the target in band.

  • The three rules

    It never boosts into a rolloff or a deep null, it never boosts narrow, and it cuts deeper than it boosts. Each region it leaves alone is named, with the reason.

Done when: The corrected prediction follows the target in band, and you can say why each refused region was left.

Next: lesson 7, Verify
Lesson 7Pro

Verify

One seat carries its own reflections. Check the correction where people stand, then listen.

  1. Step 9

    Pro

    More positions

    Capture several seats and compare them; correct what survives every position.

    Why: One seat carries its own reflections. What several seats share is what the system does.

    1. Capture at several seats, each named by where it stood.
    2. Open Positions to compare them, and correct what they share.
    3. Keep the result under the venue's name (File, Venue history). Next time there, pick it to see what changed: timing apart from level and EQ, then each trace per octave.

    When it worked: Two or more positions shown.

  • Then listen

    Play music you know at the seats you measured. The measurement shows what changed; listening decides whether to keep it.

  • Knowing when to stop

    Stop when what every position shares sits near the target. What changes from seat to seat comes from the room and the position, and filling it for one seat makes the others worse.

Done when: Two or more positions agree with the target where they share, and the system sounds right.

Coming from another analyser

Familiar: Menus along the top, the traces on the left, the screens and the generator on the right, plain buttons along the bottom, and a transfer function with magnitude, phase and coherence, its delay found and inserted. Help, Keyboard shortcuts lists the keys.

What Align does its own way

  • The channel check

    Pro

    A browser can hand a page the same signal twice. Five seconds on the Check tab prove the inputs are separate before you trust a trace.

  • The internal loop

    Pro

    With no loopback cable, Align's own output is the reference, so the delay it finds is relative, not absolute.

  • The EQ

    Pro

    Align suggests filters toward a target by three rules, and names each region it refuses and why. It suggests; you decide.

  • Your own measurements

    Pro

    A trace exported from your analyser as ASCII text opens under File, Import trace, so the EQ can work from a measurement you already trust.

  • In the browser

    Nothing to download. The analysis runs in the page, and no audio leaves the browser.

A 2, 3 or 4 way system, step by step

With Pro, the Guide button runs a whole system in this order. Each step opens the screen it needs, and it is done when the instrument reads it done.

  1. 1

    Setup

    Connect the interface, check the inputs and set the reference.

  2. 2

    Each band alone

    Find the top band's delay once and insert it, then capture every band through it.

  3. 3

    The levels

    Each band's level from its solo, the others cut to meet the lowest.

  4. 4

    Each crossover

    Auto Phase where two bands overlap: delay, polarity and all-pass.

  5. 5

    The sheet

    Every band's delay and polarity, put in a DSP channel each.

  6. 6

    EQ each band

    In the Modeler, through the band's own channel.

  7. 7

    All bands

    The processor set from the sheet and the whole system captured.

  8. 8

    More positions

    Measure at several seats and see what they share.

The words

31 words in 6 groups, each in one sentence, with more under it where one sentence is not enough.

Signals

Pink noise
Noise with equal energy in every octave: the usual signal for measuring a system.
More

It sounds even and reads flat on an octave display, falling 3 dB per octave on a per-hertz one.

White noise
Noise with equal energy at every frequency, so it sounds bright.
More

Each octave up holds twice as many frequencies, so it rises 3 dB per octave on an octave display.

Music-Noise (M-Noise)
Meyer Sound's test signal, built to behave like music.
More

Its level falls with frequency like noise, its peaks do not, so its crest factor rises with frequency. AES75 uses it to find a loudspeaker's maximum clean level and names it Music-Noise; M-Noise is Meyer Sound's name for it. Align plays Meyer's file unaltered.

Tone
One frequency, a sine wave.
Sweep
A tone gliding from low to high, which Align uses for the impulse response.
More

It measures the impulse response far more cleanly than a click would.

Pulse
Align's repeating click, every 250 or 500 ms.
More

Shaped to fall with frequency.

Measuring

Transfer function
What the system does to each frequency passing through it: raised or lowered, and shifted in time.
More

Not the same as what the signal contains, which is what the RTA shows.

Reference and measurement
The two inputs Align compares: what the system is fed, and the microphone.
More

The reference is a split of the feed, or Align's own output through the internal loop.

Delay
The time sound takes from loudspeaker to microphone, about 2.9 ms a metre.
More

Sound travels about 344 m/s at 20 C and half humidity, and about 351 m/s on a humid 30 C night; set the day's air in Config, Preferences and every distance follows it. Found and inserted so the reference and the microphone line up; left out, coherence falls at the top end.

Impulse response
The same measurement seen in time: what would come out after one click.
More

Its first peak is the direct sound, later ones reflections.

Averaging
Many measurement windows combined so the trace settles.
More

More windows are steadier and slower to follow a change.

Trace
A measurement kept, captured live or imported from a file.
More

Traces are listed in the Data bar and drawn on the graph; the EQ works from the one chosen.

The rig

Interface
The box between your microphones and the computer.
More

It turns each input's electrical signal into numbers the browser reads, and numbers back into signal for the outputs. Align reads its inputs and plays its generator through its outputs.

Input
One channel coming into the interface, from a microphone or a feed.
More

Align measures with two, the reference and the microphone, and can add more from further devices.

Internal loop
Align's own output fed back as the reference inside the browser, with no cable.
Channel check
Five seconds proving the browser keeps the two inputs apart.
More

A signal goes into input 1 only; a browser that sums the inputs hands the same signal over twice.

Summing
A browser mixing two inputs into one, so they can no longer be compared.
More

The channel check reads it as FAIL, SUMMED, and nothing measured is trusted until a check passes.

Reading the graph

Magnitude
The level part of the transfer function, in dB at each frequency.
More

With the magnitude threshold on, a strip along the top of the live trace's pane marks each frequency: solid green where the reference reaches the threshold now, dashed amber where the line holds an older reading, and it turns dashed too once the input stops, nothing where it never has. The cursor's Signal row says the same, with how long it has held.

Phase
The timing part of the transfer function, in degrees at each frequency.
More

Two systems with the same magnitude can differ here.

Coherence
From 0 to 1, how far to trust each frequency of the measurement.
More

How steady the measurement stays from one average to the next. It falls when the delay is not set, when noise covers the signal, or when reflections dominate.

Smoothing
Each point averaged with its neighbours, so small ripples fade and the trend shows.
More

Over a fraction of an octave. It changes the view, never the data kept.

RTA (spectrum)
What a signal contains at each frequency, read from one input.
More

Not the transfer function, which is what the system does.

Correcting

Target
The response shape you tune toward.
More

Align fits its EQ to it.

EQ filter
A filter that raises or lowers part of the spectrum.
More

A peak around one frequency, a shelf above or below one, or a high or low pass that removes what lies below or above it. Align's automatic EQ places peaks; your own filters can be any of these.

Q
How narrow a filter is: the higher the Q, the narrower the band.
More

A Q of 1.41 spans about one octave.

The three rules
Align's limits on its own automatic EQ.
More

It will not boost into a rolloff or a deep null; it will not boost a dip narrower than about half an octave, a cancellation that moves when the microphone moves; and it cuts deeper than it boosts, boosts capped at 3 dB by default.

Position
One place the microphone stood for a capture.
More

A response measured at one seat carries that location's own acoustical anomalies too.

Spatial average
Measurements from several positions averaged into one.
More

What the system does across the audience then stands out from what happens at a single seat.

Levels

dBFS
Decibels below the largest value the interface records, 0 dBFS.
More

Half of full scale is -6 dBFS. Reaching 0 dBFS clips the signal and spoils the measurement.

dB SPL
Sound pressure level: decibels above the quietest 1 kHz tone a good ear hears.
More

That reference is 20 micropascals. Read only with a calibrated microphone.

Crest factor
How far a signal's peaks stand above its average level, in dB.
More

Peak less RMS.

Try it on your own rig

The RTA, the spectrograph, the SPL meter, pink noise and the Fill and delay planner are free in your browser, with no account. To measure through an audio interface, use Chrome or Edge on a computer.